Oil level of the gear box is an important parameter to
be monitored. Damages expected due to low oil level are
obvious and need not to be elaborated.
Old float type switches rely on buoyancy of the oil which
changes with the impurities in the oil. Trip level also
depends on the strength on the magnet used and needs adjustment
for the individual piece.
In ACD switch, the sensing element is Capacitance Sensor
whose performance is highly consistent, such that all the
parameters can be precisely factory set and no in-situ adjustments
are necessary.
The switch is designed in a weatherproof enclosure confirming
to IP 65. (can be supplied in Flame Proof enclosure)